OM-CP Intrinsically Safe Temperature Data Logger

Intrinsically Safe Temperature Data Logger

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The OM-CP-TEMP1000IS-A2 is an Intrinsically Safe temperature data logger designed for hazardous locations. Its 316 stainless steel enclosure and intrinsically safe certification for Class 1 Division 1 Group ABCD, Class 1 Division 2 Group ABCD and Temperature Class T4A make it suited to hostile and potentially explosive environments.

• EtO sterilization processes.
• Environmental studies.
• Other hostile environments requiring an intrinsically safe temperature record.

Operating Conditions & Performance

Temperature is measured by a Resistance Temperature Detector (RTD) over a range of -40 °C to +80 °C (-40 °F to +176 °F), with a temperature resolution of 0.01 °C (0.018 °F) and a calibrated accuracy of ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F).

The logger holds 65,536 Readings and records at a reading rate of 1 reading every second up to 1 reading every 24 hours, and may be used with a PC to monitor and record data in real time. It is powered by a Tadiran TL-2150 3.6V lithium battery, included and user replaceable in a non-hazardous location, with a battery life of 2 years typical at 15 minute reading rate. Data is date and time stamped in °C, °F, K, °R, and time accuracy is 10 seconds / month across 0 °C to 50 °C.

The enclosure is 316 Stainless Steel/Radel and is not rated for submersion; do not submerge this product to retain the IS rating. The operating environment is -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (case properly sealed). Approvals include CE, FM Class 3600, Rev. Jan 2018, FM Class 3610, Rev. Jan 2018, CAN/CSA-C22.2 No. 60079-0:15 and CAN/CSA-C22.2 No. 60079-11:14.

Configuration Options

The OM-CP-TEMP1000IS-A2 is offered with a choice of probe length, which changes the overall dimensions and weight while keeping the same RTD sensing and intrinsically safe rating:

• 1 inch probe: 2.66 in x 0.97 in dia. (67.6 mm x 24.6 mm dia.), 2.1 oz (60 g).
• 2 inch probe: 3.94 in x 0.97 in dia. (100.1 mm x 24.6 mm dia.), 2.4 oz (68 g).
• 5.25 inch probe: 7.19 in x 0.97 in dia. (182.6 mm x 24.6 mm dia.), 2.7 oz (76 g).
• 7 inch probe: 8.94 in x 0.97 in dia. (227.1 mm x 24.6 mm dia.), 2.8 oz (78 g).

Across all probe lengths the logger offers software programmable immediate start or delay start, up to 24 months in advance, digital calibration through software, and Sterilization Units and Pasteurization Units lethality equations within the software. Data retrieval uses the OM-CP-IFC400 docking station or the OM-CP-IFC406 6 Port, Multiplexer docking station, and the OM-CP-BAT113 is the replacement 3.6 V lithium battery.

Key Product Differences

The series is ordered from the following model and accessories:

• OM-CP-TEMP1000IS-A2 - Intrinsically Safe Temperature Data Logger with 1 inch probe.
• OM-CP-IFC400 - Docking station with USB cable.
• OM-CP-IFC406 - 6 Port, Multiplexer docking station with USB cable.
• OM-CP-BAT113 - Replacement 3.6 V lithium battery.

  • Certified Intrinsically Safe
  • SGS Certified to meet FM3600 and FM3610 standards
  • Software Battery Life Indicator
  • 316 Stainless Steel Enclosure

 

Additional Features 1SGS, FM, Intrinsically Safe
Battery lifeup to 2 yr
Battery Size and Type3.6V Li-ion
CalibrationDigital calibration through software
Data InterfaceUSB
Data Interface NoteDocking Station to USB (Sold Seperately)
Diameter0.97 in
Height2.66 in
Materials316 Stainless Steel
Measurement TypeTemperature
Memory65536
Number of Measurements1
Operating Temperature, Max80 °C
Operating Temperature, Min-40 °C
Probe Length1 in
Real Time RecordingMay be used with PC to monitor and record data in real time
Relative Humidity Accuracy± 3% RH
Relative Humidity, Max1
Relative Humidity, Min0%
Samples,Max650000
Sampling Rate1 Hz (1 update/second)
Sampling Rate Note1 reading every second to 1 every 24 hours.
Series IDOM-CP-TEMP1000IS-Lgr
Software CompatibilityWindows XP SP3/7/8/10
Supply Power TypeBattery
Temperature Accuracy± 0.5 °C
Temperature Measurement, Max80 °C
Temperature Measurement, Min-40 °C
Temperature Resolution0.01 °C
Temperature Sensor TypeRTD
Temperature Sensor Type NoteResistance Temperature Detector
Time Accuracy10 seconds / month 0 °C to 50 °C
Weight60 g
Weight Note1 inch probe: 2.1 oz (60 g) 2 inch probe: 2.4 oz (68 g) 5.25 inch probe: 2.7 oz (76 g) 7 inch probe: 2.8 oz (78 g)
  • Download

    Data Sheet - OM-CP Intrinsically Safe Temperature Data Logger

    Download
  • Download

    Manual - OM-CP Intrinsically Safe Temperature Data Logger

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more