Skip to main content
Press Enter
OMEGA

OM-CP-PROCESS101A-20MA DC Current Data Logger

DC Current Data Logger

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega OM-CP-PROCESS101A Series is a battery-powered DC current data logger designed for measuring and recording direct current signals. As part of the NOMAD® family, these devices capture process variables at user-specified intervals ranging from once every 2 seconds to once every 12 hours. The series supports real-time monitoring and recording when connected to a PC via USB.

Operating Conditions & Performance

The OM-CP-PROCESS101A operates within an ambient temperature range of -40 to 80°C (-40 to 176°F) and humidity levels from 0 to 95% RH non-condensing. The device features a nominal response time of 133 ms.

Performance specifications vary by input range as documented in the series data sheet:

• ±20 mA Range (Measurement: -2 to 30 mA): Resolution is 0.5 µA with an accuracy of ±0.05% FSR and overload protection up to ±316 mA.
• ±160 mA Range: Resolution is 5 µA with an accuracy of ±0.05% FSR and overload protection up to 1A.
• ±3A Range: Resolution is 100 µA with an accuracy of ±0.15% FSR and overload protection up to 6A.

All ranges share a common input voltage range of 0 to 2.5V. The device includes memory wrap functionality, allowing it to continue logging after reaching its 1 million reading storage capacity.

Power and Storage

Power Supply: Powered by an included 3.6V lithium battery with a typical life of 10 years at a 15-minute reading rate.
• Status Indicators: A green LED blinks every 10 seconds to indicate logging or every 15 seconds in delay start mode; a red LED indicates low battery and/or full memory status.

Configuration Options

The series is available with three distinct measurement ranges, each configurable for specific current levels. The standard housing material is ABS Plastic with removable screw terminals for electrical connection.

• Housing Options: An optional weatherproof enclosure (OM-CP-WATERBOX101A) provides NEMA 4 (IP65) protection.
• Data Retrieval: Requires the OM-CP-IFC200 interface cable and Windows software for programming, data download, and real-time monitoring. The device connects via USB; a serial port is not used on this specific series model.
• Firmware & Security: Features field-upgradeable firmware and optional password protection.

Available Accessories and Options

• OM-CP-IFC200: Windows software and 1.8 m (6') USB interface cable.
• OM-CP-BAT105: Replacement 3.6V lithium battery.
• OM-CP-CONNECTOR-3: Replacement 3 position terminal block.
• NIST calibration certificate: Available for all ranges as an optional add-on (e.g., -CERT suffix).

Key Product Differences

The OM-CP-PROCESS101A Series is distinguished by its input range and the inclusion of a NIST calibration certificate. The base models are identified as follows:

• OM-CP-PROCESS101A-20MA: DC current data logger, ±20 mA range.
• OM-CP-PROCESS101A-160MA: DC current data logger, ±160 mA range.
• OM-CP-PROCESS101A-3A: DC current data logger, ±3A range.

Variants with the "-CERT" suffix (e.g., OM-CP-PROCESS101A-20MA-CERT) include a NIST calibration certificate. The series carries CE approval and offers an optional 5-year warranty.

• USB Cable and Software (Model OM-CP-IFC200) Sold Separately and Required to Program the Unit
• 10 Year Battery Life
• 4 Hz Reading Rate
• Multiple Start/Stop Function
AlarmProgrammable high and low limits; alarm is activated when current reaches or exceeds set limits
Baud Rate115200
Calibration Accuracy±0.05%
Calibration NoteDigital calibration through software, automatically recorded within device
Conversion Time133 ms
Data InterfaceUSB
Electrical ConnectionRemovable Screw Terminal
Frequency Rejection50 to 60 Hz
Height1.4 in
Housing Depth1.5 in
Housing Height2.9 in
Housing Width5.8 in
Input Voltage0 to 2.5 V
LED FunctionalityGreen LED Blinks: 10 second rate to indicate logging 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory
Length0.6 in
MaterialsAluminum, ABS
Measurement TypeCurrent
Memory1,000,000 readings
Memory Note1,000,000 readings; software configurable memory wrap 333,000 readings in multiple start/ stop mode
Number of Channels1
Operating Temperature, Max80 °C
Operating Temperature, Min-40 °C
Real Time RecordingThe device may be used with PC to monitor and record data in real-time
Relative Humidity0 to 95% RH
Sampling Rate Note4 Hz to 1 reading every 24 hours
Series IDOM-CP-PROCESS101A-Series
SoftwareXP SP3/Vista/7 and 8
Supply Power3.6 V Lithium Battery
Supply Power Note10 Year Battery Life Typical, at a 15 Minute Reading Rate
Supply Power TypeBattery
Temperature Coefficient< ±50 ppm/ºC
Time Accuracy±1 minute/month (stand alone data logging)
Voltage Measurement RangeN/A
Weight24 g
Width2.2 in
  • Download

    Manual - OM-CP-PROCESS101A-20MA DC Current Data Logger

    Download
  • Download

    Data Sheet - OM-CP-PROCESS101A-20MA DC Current Data Logger

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more