 The 130 Series reversing speed control is designed to provide instant reversing, quick precise stopping or rapid cycling for a wide range of DC motor applications. The 130 Series reversing control outperforms other dynamic braking and reversing controls by utilizing unique zerospeed detect and dynamic braking circuits. These circuits eliminate the contact arcing and failed braking problems associated with other reversing and dynamic braking controls. The zero speed detect circuit also eliminates motor plug reversing problems. In the event of a power loss or emergency stop condition, the 130 Series control will drop into a dynamic brake condition to safely and quickly bring the motor to a stop and remain there until power is reapplied and a run condition is recognized.

 
• Provides DC Motor Speed Control with Reversing Capability
• Speed Regulation is ±1% of Base Speed
• Adjustable Minimum/Maximum Speed
• Adjustable Current Limit
AC Input Voltage±10% of rated line voltage
Acceleration0.5 seconds
Amps-DC Output
130LC100 and 132LC200500 mA to 5.5 ADC*
130HC100 and 132HC200500 mA to 10 ADC
Controller Overload Capacity200% for one minute
Current Limit Trimpot Range
Models 130xx100 and 132xx2001 to 18 ADC
Deceleration0.5 seconds
Dimensions
LC Model126.16 W x 107.95 L x 68.27 mm D (4.96 x 4.25 x 2.68')
HC Model158.75 W x 177.8 L x 103.2 mm D (6.25 x 7.0 x 4.06')
Weight
LC Models489.87 g (1.08 lb)
HC Models1496.80 g (3.30 lb)
Drive Service Factor1.0
Efficiency85% typical
Input Frequency50 or 60 Hz
Trimpot Speed Range
Maximum60 to 110% of base speed
Minimum0 to 30% of maximum speed
Power Devices
Shunt Field Voltage100 Vdc for 120 Vac input; 200 Vdc for 240 Vac input
Shunt Field Current1 amp DC maximum
Speed ControlVia 5 kΩ 0.5 W potentiometer or 0 to 10 Vdc isolated signal
Speed Range50:1
Speed Regulation±1% of base speed
Temperature Range-10 to 45°C ambient (15 to 115°F)
Terminal Block Torque Setting4.4 in. lb. maximum or 0.05 Nm
Transient ProtectionG-Mov
TriggerOpto-isolator
Start/Brake Cycle Per Minute
LC Models3 per min**
HC Models30 per min**
Operating Conditions
Temperature-10 to 45°C (14 to 113°F)
AC Input voltage±10% rated line voltage
Input Frequency50/60 Hz
  • Thumbnail of document Data Sheet - OMDC-130LC100 DC Motor Speed Control w/Reversing Capability
    Download

    Data Sheet - OMDC-130LC100 DC Motor Speed Control w/Reversing Capability

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more