Skip to main content
Press Enter
OMEGA

OMNI-AMP IV-13-115 Rugged Epoxy Encapsulated Thermocouple Amplifier

Thermocouple Amplifier

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega OMNI-AMP IV is a high-performance, rugged epoxy encapsulated thermocouple amplifier designed for signal conditioning in industrial environments. It provides amplification and cold junction compensation for Type E, J, T, or K thermocouples using a 10 mV/°F scale factor. The series also accommodates Types R, S, and B when configured with the optional 1 mV/°F scale factor option.

Operating Conditions & Performance

The amplifier operates within an ambient temperature range of 0 to 55°C (32 to 130°F) and supports a storage temperature from -20 to 80°C (-4 to 175°F). It delivers a ±10 VDC output into a minimum load resistance of 10 kΩ. Performance specifications include an input impedance of 2 MΩ (differential), infinite resolution, and nonlinearity of ±0.005%. Stability after a 30-minute warm-up is rated at 2 μV/°C (1 μV/°F) for zero drift and ±0.01%/°C (±0.006%/°F) for span stability, with long-term span stability of ±0.05%. The unit features a frequency response that rolls off 40 dB/decade after dropping 3 dB at 1.5 Hz.

Electrical protection includes input tolerance up to 115 VAC or DC common mode or differential, and the output is continuous short circuit proof. Noise rejection capabilities include a Common Mode Rejection Ratio (CMRR) of 120 dB minimum @ 60 Hz and a Normal Mode Rejection ratio of 80 dB minimum @ 60 Hz.

Key Performance Metrics

• Cold Junction Compensation: ±0.045 °C/°C (±0.025 °F/°F)
• Noise (RTI) 0 to 1.5 Hz: 1.4 μVRMS
• Common Mode Range: +10 to -10 VDC or 20 Volts peak-to-peak AC
• Power Consumption: 3 VA maximum @ 115 VAC (or 230 VAC)

Configuration Options

The OMNI-AMP IV series is configurable across several dimensions to meet specific installation and measurement needs. The unit features rugged terminal strips for electrical connections, requiring a screwdriver for termination.

Housing and Mounting

• Enclosure: Rugged epoxy encapsulated housing (100% encapsulated).
• Dimensions: 73 H x 95 W x 51 mm D (2.87" x 3.75" x 2.0").
• Weight: 455 g (18 oz).
• Mounting Options: Supplied with bolts for standard mounting; a DIN rail mounting kit is available as accessory model number DIN400.

Signal and Power Configuration

• Scale Factor: 10 mV/°F (standard) or 1 mV/°F (optional for Types R, S, B).
• Burnout Direction: Configurable as Up Scale (-01 code) or Down Scale (-02 code).
• Power Supply: Available in 115 VAC @ 3 VA maximum (code -115, range 105 to 125 Volts AC, 50-60 Hz) or 230 VAC (code -230, range 210 to 250 Volts AC, 50-60 Hz).

Key Product Differences

The series is distinguished by the thermocouple type supported and the resulting scale factor. Models ending in "3" (e.g., OMNI-AMP IV-13-115) utilize a 10 mV/°F output for Types J, K, T, and E. Models ending in "4" (e.g., OMNI-AMP IV-14-115) utilize a 1 mV/°F output specifically for Types R, S, and B.

Model numbers further differentiate the burnout direction: codes starting with "1" indicate Up Scale (increase in temperature), while codes starting with "2" indicate Down Scale (decrease in temperature). The final digits denote the power line voltage compatibility (-115 for 105 to 125 VAC, -230 for 210 to 250 VAC).

Wire color coding is provided per thermocouple type: J (White/Red), K (Yellow/Red), T (Blue/Red), E (Purple/Red), and R/S/B (Black/Red). The terminal strip assignments include dedicated terminals for OUTPUT, CMN, AMBIENT OUT, +INPUT, -INPUT, and AC power connections.

• 100% Encapsulated
• 2µV/°C Zero Stability
• 0.025°F/°F Reference Junction Stability
• Up or Downscale TC Burn-out
Bandwidth3 dB down at 1.5 Hz 40 dB/decade roll-off
CMRR120 dB min @ 60 Hz
Cold Junction Compensation± 0.045°C/°C
Common Mode Voltage+10 to -10 Vdc or 20 Volts peak-to-peak ac
Electrical Output± 10 V into 10 kΩ min
Height73 mm
Impedance Input2 MΩ
Input Noise0 to 1.5 Hz: 1.4 µVRMS (RTI)
Input Range40 to 1500
Length51 mm
Long Term StabilityZero: ± 1µV/Month;Span: ± 0.05%; Stability of zero point - 2 µV/°C , Span stability - ± 0.01%/°C
NMRR80 dB min @ 60 Hz
Non-Linearity± 0.005 %
Operating Temperature, Max55 °C
Operating Temperature, Min0 °C
Output SignalVoltage
ProtectionOutput Protection: Continuous short circuit proof, Input Protection: Up to 115 Vac or Vdc common mode or differential Output Port
ResolutionInfinite
Series IDOMNI-AMP-IV-Srs-TC-Amp
Storage Temperature, Max80 °C
Storage Temperature, Min-20 °C
Supply Power115 Vac @ 3 VA max
Supply Power TypeAC
Weight455 g
Width95 mm
  • Download

    Data Sheet - OMNI-AMP IV-13-115 Rugged Epoxy Encapsulated Thermocouple Amplifier

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more