Skip to main content
Press Enter
OMEGA

OS101E RS232 Output IR Sensor w/Optional Display

RS232 Output IR Sensor with Optional Display

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!

 Supported Applications

The OMEGA OS100E Series miniature infrared transmitters provide non-contact temperature measurement across an industrial range of -18 to 538°C (0 to 1000°F). Each unit pairs a remotely mounted infrared sensor head with a high-performance, microprocessor-based signal conditioner, so the small sensor head can be placed in confined, hard-to-reach places and harsh environments while the transmitter is mounted where it is convenient to wire and read.

Typical uses take advantage of the remote head, the analog and RS232 outputs, and the optional laser sighting:

• Fixed-point process temperature monitoring in tight or hostile locations.
• Integration with meters, chart recorders and PLCs through a choice of analog outputs.
• PC-based configuration and readout over the RS232 interface.
• Targeting assistance using the OS100-LS laser sighting accessory.

This product is not intended for medical use or use on humans. All connections should be made with a shielded cable, 24 AWG stranded wire rated 300V, 105°C (221°F), PVC insulation.

Operating Conditions & Performance

The transmitter measures -18 to 538°C (0 to 1000°F) with an optical field of view of 6:1 (distance to spot size) and a spectral response of 5 to 14 microns. Accuracy, referenced at 22°C (72°F) ambient and emissivity of 0.95 or greater, is ±2% rdg or 2.2°C (4°F), whichever is greater, with repeatability of ±1% rdg. Response time is 100 ms (0 to 63% of final value) and emissivity is adjustable from 0.1 to 1.00.

Power is 12 to 24 Vdc @ 150 mA, with overload protection of 500 mA on the family supply requirement. Minimum load resistance is 1 kΩ for the 0 to 5 Vdc output and 2 kΩ for the 0 to 10 Vdc output.

The housing is NEMA 4 (IP65) die-cast aluminium. Main housing dimensions are 65.5 W x 30.5 D x 115.3 mm L (2.58 x 1.2 x 4.54 inch), the sensor head is 25.4 mm (1 inch) diameter and 63.5 mm (2.5 inch) long, and the unit weighs 272 g (0.6 lb). Operating limits differ by section:

• Main transmitter ambient: 0 to 50°C (32 to 122°F).
• Sensor head: 0 to 70°C (32 to 158°F).
• Sensor head, HT model: 0 to 85°C (32 to 185°F).
• Sensor head with OS100-WC water cooling jacket: 0 to 200°C (32 to 392°F).

Operating relative humidity is less than 95% RH, non-condensing. The series is CE marked and, with the optional laser, complies with FDA 21 CFR 1040.10 as a Class II laser product and European Class 2 per EN60825-1/11.2001; maximum laser optical power is less than 1 mW @ 25°C (77°F).

Configuration Options

Model identity follows OS100E - output - display - temperature. Two base platforms set the display capability:

• OS101E transmitters provide the measurement and outputs without a local display.
• OS102E transmitters add a 4-digit LED display that is switchable between °C and °F.

Output options

The output suffix selects the electrical interface:

• OS101E-MV — 1 mV/°C or °F output.
• OS101E-V1 — 0 to 5 Vdc output.
• OS101E-V2 — 0 to 10 Vdc output.
• OS101E-MA — 4 to 20 mA output.
• OS101E-K — Type K thermocouple output.

High temperature heads

An HT suffix denotes the high temperature sensor head, which extends the head rating from 0 to 70°C (32 to 158°F) up to 0 to 85°C (32 to 185°F). HT versions include OS101E-MA-HT and OS101E-V2-HT. Where still higher head exposure is required, the OS100-WC water cooling jacket allows sensor-head operation up to 0 to 200°C (32 to 392°F).

Key Product Differences

OS101E transmitters (no display)

• OS101E-MV — 1 mV/°C or °F output.
• OS101E-V1 — 0 to 5 Vdc output.
• OS101E-V2 — 0 to 10 Vdc output.
• OS101E-MA — 4 to 20 mA output.
• OS101E-K — Type K thermocouple output.
• High temperature heads: OS101E-MV-HT, OS101E-V1-HT, OS101E-V2-HT, OS101E-MA-HT, OS101E-K-HT.

OS102E transmitters (with LED display)

• OS102E-MV — 1 mV/°C or °F output and LED display.
• OS102E-V1 — 0 to 5 Vdc output and LED display.
• OS102E-V2 — 0 to 10 Vdc output and LED display.
• OS102E-MA — 4 to 20 mA output and LED display.

Accessories

• OS100-MB — mounting bracket.
• OS100-DR — DIN rail mounting adaptor.
• OS100-AP — air purge collar.
• OS100-WC — water cooling jacket, up to 200°C.
• OS100-LS — laser sighting accessory.
• OS100-CA15FT — sensor head extension cable, 4.6 m (15').
• OS100-CA25FT — sensor head extension cable, 7.6 m (25').
• TX8-100 — power/output cable, 30 m (100').
• PSR-24S — regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL.
• PSU-93 — unregulated power supply, 16 to 23 Vdc, 300 mA max, screw terminal.

  • -18 to 538°C (0 to 1000°F) Temperature Range
  • Adjustable Emissivity from 0.1 to 1.0
  • 5 Different Analog Output Models
  • LED Display Model Available
Accuracy± 2 %
Air Flow rate1 CFM
Alarm Deadband5.5°C (10°F)
Alarm SetpointAdjustable, 0 to 100%
Cable Length6 ft
Control OutputOpen drain
Data InterfaceRS232
Data Interface NoteSerial RS232, 2-way
Emissivity, Max1
Emissivity, Min0.1
Emissivity Note0.1 to 1.00, adjustable
Enclosure RatingsIP65, NEMA Type 4
Field of view6:1
Field of View Note6:1 (distance/ spot size)
Housing Height30.5 mm
Housing Length115.3 mm
Housing MaterialAluminum
Housing Width65.5 mm
Laser Outputfalse
Operating Temperature, Min0 °C
Process Temperature, Max538 °C
Process Temperature, Min-18 °C
Relative Humidity, Max0.95
Relative Humidity NoteLess than 95% RH, non-condensing
Repeatability± 1%
Sensor Diameter25.4 mm
Sensor Length63.5 mm
Series IDOS100E
Spectral Response, Max14 μm
Spectral Response, Min5 μm
Supply Voltage12 to 24 Vdc
Thermal shockAbout 30 minutes for 25°C (77°F) abrupt ambient
Warm-Up Period, Max3 m
Warm-Up Period, Min0 m
Water Flow Rate0.25 GPM
Water Flow Rate Note0.25 GPM, room temperature
Weight272 g
  • Download

    Data Sheet - OS101E RS232 Output IR Sensor w/Optional Display

    Download
  • Download

    Manual - OS101E RS232 Output IR Sensor w/Optional Display

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more