OSXL-101 100°C to 800°C Temperature Fixed Mount Thermal Imager

Fixed Mount Thermal Imager

Normally ships in
3-4 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega OSXL-101 Series is a fixed-mount thermal imager designed for temperature monitoring in the range of 100 °C to 800 °C. As part of the infrared and thermal imaging category, this series provides non-contact measurement capabilities suitable for industrial process observation.

Operating Conditions & Performance

The OSXL-101 Series operates within a defined temperature envelope from 100 °C to 800 °C. Specific performance metrics such as accuracy class, response time, and ambient operating limits are not detailed in the current documentation for this series.

Configuration Options

The OSXL-101 Series is available with specific model configurations identified by their part numbers:

• OSXL-101: Standard fixed-mount thermal imager configuration.
• OSXL-101-25H: A variant of the series offering distinct hardware or mounting specifications as indicated by its suffix code.

Key Product Differences

The primary distinction within the OSXL-101 Series lies in the model codes, which differentiate between the base unit (OSXL-101) and the specific variant (OSXL-101-25H). Detailed technical differences regarding housing materials, output signal types, or sensor elements are not specified in the available source data.

• Narrow FOV 25° x 25°

• High Temperature 100° to 800°C (212° to 1472°F)

• Easy to Use and Implement

Accuracy± 3 °C (± 5.4 °F)
Accuracy Detail± 2% of reading or ± 3° C whichever larger (at ambient temp of 25°C ± 2° C)
Alarm2 SPST (non-voltage contactoutput)
Application SoftwareRequirements OS: Windows® 2000 (SP4 or later)/XPNista (Windows XP or later recommended) NET Framework 2.0 or later (required) Memory Windows 2000/XP: 1 GB recommended (512 MB or more) Windows Vista: 2 GB or more recommended CPU Windows 2000/XP: 1.5 GHz or faster recommended Windows Vista: 2 GHz or faster recommended Basic Function When the LAN settings are completed correctly between a PC and the thermal image sensor and the LAN communication is established, thermal image screen will appear; the thermal images up to 4 sensors can be displayed with this application software, and the simultaneous display for images and the individual display for each sensor can be switched. Various Settings of Sensor LAN settings/alarm settings of the sensors/emissivity setting Data Storage Image temperature data storage (temperature data/csv for 2256 pixels)/ Thermal image screen storage (JPEG) Image Processing Screen averaging/spatial smoothing/ median filter/rotation/maximum and minimum values indications Trend Graph By specifying a graph area, data can be displayed by the trend graph and the graph data can be stored by setting. (max 8 areas) Alarm Settings by the Application Software • By specifying a zone, alarms can be set (max 8 areas) • The zone alarm as set in the application software are separate and in addition to alarms set in the sensor
Capturing ModePLC Connection
Capturing Mode NotePLC Connection • The temperature data is outputted row-by-row Horizontally by a command from PLC, etc
Data InterfaceEthernet
Detector Dimension48 x 47 Pixels
Detector TypeThermopile array
Emissivity, Max1
Emissivity, Min0.1
Enclosure RatingsIP65, NEMA Type 4
Enclosure Ratings NoteNEMA 4 (IP65) (with provided exclusive cable and tripod screw)
FocusFixed
Frame Speed3 fps
Frame Speed Note3 fps (1 fps for alarm output)
FunctionsMonitoring Mode The temperature data is outputted continuously by a command from the PC. Capturing Mode The temperature data is outputted row•by•row horizontally by a command from PLC, etc. Connectivity Up to 4 sensors can be connected to a PC via LAN and viewer software allows you to monitor thermal images, measuring temperature and alarms.
Housing MaterialPolycarbonate
Inrush CurrentMaximum 1.3A @12 Vdc (the inrush current should beconsidered for the selection of power)
Monitor Mode NoteMultiple Unit Connection (LAN) • p to 4 sensors can be connected • Monitoring and alarm outputs from sensor can be used together Single Unit Usage • Single unit can monitor 1 area and has 2 alarm outputs • When alarm goes on, the unit stores 1 image to the memory • Image saving updates every occurrence of alarm • Reading the data from host PC is possible
MountingFixed Mount Thermal Imager
Operating Temperature, Max50 °C
Operating Temperature, Min-10 °C
Radius Resolution21.8 mrad
Relative Humidity Note10 to 80% RH (no dew condensation)
Series IDOSXL-101 Series
Temperature Resolution0.5 °C
Wavelength Dimension10 μm
Wavelength PositionCenter
Weight150 g
Weight NoteApproximately 150 g (5.2 oz) (sensor only)
  • Download

    Manual - OSXL-101 100°C to 800°C Temperature Fixed Mount Thermal Imager

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more