Skip to main content
Press Enter
Starting at $580.50CAD
Configure
In Stock *
Precision Digital

PD150 Vigilante II Series Alarm Annunciator

In Stock *

Compact, panel-space saving, four and eight channel, low-cost, easy to use, perfect for replacing stand-alone lights

Starting at
$580.50CAD
Some configurations are in stock for immediate delivery!
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The Vigilante II annunciators are compact, panel-space saving, four and eight channel annunciators loaded with features found previously in annunciators three or four times their size. Yet despite all the traditional annunciator features that are included in the Vigilantes, they are still very much low-cost, easy to use alarm annunciators perfect for replacing stand-alone lights!

The Vigilantes are housed in shallow depth, 1/8 DIN enclosures for easy and convenient mounting. They can be programmed for all the common ISA alarm sequences, accept switch, transistor, and logic level inputs, and can be supplied with free custom printed message labels.

The Vigilantes' industrial-grade design, NEMA 4X front, wide operating temperature range, and sunlight readable alarm indicators make them well suited for outdoor alarm applications. Front panel buttons and screw terminal connectors located at the rear of the instrument are provided for Silence, Acknowledge, and Reset functions. A built-in horn provides audible indication of alarm condition and up to two relays can be used to control external devices such as beacons, horns, or buzzers.

     

• 8 Field Selectable Sequences
• All Common ISA Sequences Including First-Out
• Switch, Transistor, and Logic Level Inputs
• 4 or 8-Point Monitoring
• Free Custom Message Labels
• Type 4X, NEMA 4X, IP65 Front
• Universal Power Supply 85-265 VAC
• 12-36 VDC/12-24 VAC Power Option
• Built-In 85 dB Horn
• 2 SPDT Relays for Alarm Activated Devices
• 24 VDC Isolated Power Supply (AC Models)
• Multiple-Unit First-Out Indication
• Silence, Acknowledge, and Reset Functions
• Sunlight Readable Indication
• Shallow Depth 1/8 DIN Case

Display
Alarm MessagesCustom printed adhesive clear labels.
AreaPD154, 1.25" x .60" (32 mm x 15 mm), 4 messages PD158, 1.25" x .25" (32 mm x 6 mm), 8 messages
User specified size and length, up to 4 lines (PD154) or 2 lines (PD158) of 14 characters of size 9 pt fonts.
Programming MethodsRear 4-position switch for sequence selection and horn operation. Three front panel push buttons for NO/NC input selection, sequence option, and operation.
Audible Alarm85 dB internal horn.
Noise Filter40 ms debounce on inputs and external push buttons.
Shared First-Out Systems1 ms unit-to-unit delay. Maximum of 200 units in the shared first-out system.
Non-Volatile MemoryAll programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC, 50/60 Hz; 90-265 VDC, 20 W max; or 12-36 VDC, 12-24 VAC, 6 W max.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow. Up to 6 annunciators may share one 5 A fuse
Isolated Power Supply24 VDC ± 10% @ 200 mA max Standard on 85-265 VAC powered units only.
Isolation4 kV input/output-to-power line.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalOperating temperature range: -40 to 65°C.
Storage Conditions-40 to 85°C. Relative humidity: 0 to 90% non-condensing.
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire
Enclosure1/8 DIN, high impact plastic, UL 94V-0, front color: black
Mounting1/8 DIN panel cutout required. Two panel mounting brackets included.
Tightening TorqueScrew terminal connectors: Gray: 4.5 lb-in (0.5 Nm). Green: 5 lb-in (0.5 Nm)
Overall Dimensions (H x W x D)4.68" x 2.45" x 4.19" (62 mm x 119 mm x 106 mm)
E160849; 508 Industrial Control Equipment
Warranty3 years parts & labor
Input TypesNO or NC switches: No external excitation required.
Open Collector TransistorOpen circuit voltage approx. 3.3 VDC.
Logic LevelsLOW = 0 to 0.9 VDC,
HIGH = 2.4 to 28 VDC
Update Rate41 ms following alarm state; 1 ms for alarm state clear.
SequencesInput follower, ISA Sequences A, F1A, F2A, F3A, M, F1M, and F3M per ISA Standard ISA-18.1-1979 R2004.
Sequence OptionsA, F1A, F2A, F3A, M, F1M, F2M, and input follower with selectable options -1 (silence pushbutton), -4 (no lock-in), and -6 (no horn) per ISA Standard ISA-18.1-1979 R2004
Rating2 SPDT (Form C); rated 3 A @ 30 VDC or 3A @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads.
Electrical Noise SuppressionA suppressor (snubber) should be connected to each relay contact switching inductive loads to prevent disruption to the microprocessor's operation. Recommended suppressor value: 0.01 µF/470 Ω, 250 VAC (PDX6901).
Relay OperationRelay 1: Alarm state until alarm is acknowledged. Relay 2: Alarm state if any channel indicating alarm condition.
Fail-Safe OperationProgrammable independent for each relay.
Note: In fail-safe mode, relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.
  • Thumbnail of document Data Sheet - PD150 Vigilante II Series Alarm Annunciator
    Download

    Data Sheet - PD150 Vigilante II Series Alarm Annunciator

    Download
  • Thumbnail of document Manual - PD150 Vigilante II Series Alarm Annunciator
    Download

    Manual - PD150 Vigilante II Series Alarm Annunciator

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more