What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight and up to 100 feet away. Based on Precision Digital's popular line of ProVu® digital panel meters, the Helios can satisfy a wide variety of level, flow, temperature, pressure, & weight applications. It is available with models that accept 4-20 mA, thermocouple, RTD, pulse, strain gauge, AC and DC volts and current, and even Modbus®.

Go with the Helios PD2-6310 when you need to do batch controlling using a pulse output flowmeter. The PD2-6310's huge display means operators don't have to be close up to the instrument to monitor the status of the batching application. And its IP65 rated field mountable enclosure allows the PD2-6310 to be mounted in wet, dusty, and dirty areas. The PD2-6310 can handle single and multi-stage batching applications.

Input

Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave

Helios Features

• Large 1.80" Digits
• Dual Line Display
• Six Full Digits on Each Line
• Readable From 100 Feet Away
• Superluminous Sunlight Readable Display
• IP65 Rated Field Mountable Enclosure
• Great for Outdoor Use: -40 to 150°F (-40 to 65°C)
• Program the Meter from a PC with Onboard USB and MeterView® Pro

PD2-6310 Features


• 5, 10, or 24 V Flowmeter Power Supply
• K-Factor, Internal Scaling, or External Calibration
• Start, Batch, Pause, & Stop with Front Panel Buttons
• Display Batch Total + Rate, Grand Total, Batch Count or Preset
• Single or Multi-Stage Batching with up to 8 Relays
• Automatic Overflow Protection
• Manual Control or Automatic Batching
• 32-Point Linearization
• On-board Digital Input (for Remote Reset)
• Count Up or Down, Total & Grand Total

DisplayTwo lines with 1.8" (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Display IntensityEight user selectable intensity levels
Display Update Rate5/second (200 ms)
Over RangeDisplay flashes 999999
Under RangeDisplay flashes -99999
Display AssignmentDisplay lines 1 & 2 may be assigned to rate, total, grand total, batch count, preset, set points, units (lower display only), alternating R & T, R & GT, preset & rate, max & min, or a Modbus display register. Any rate/total/grand total display may be programmed to alternate with a custom unit or tag.
Programming MethodsFour programming buttons, digital inputs, PC and MeterView Pro software, or Modbus registers.
Noise FilterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationAll ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
PasswordThree programmable passwords restrict modification of programmed settings.
Pass 1: Allows use of function keys and digital inputs
Pass 2: Allows use of function keys, digital inputs and editing set/reset points
Pass 3: Restricts all programming, function keys, and digital inputs.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
Isolated Transmitter Power SupplyTerminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
Non-Volatile MemoryAll programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalOperating temperature range: -40 to 150°F (-40 to 65°C); Storage temperature range: -40 to 185°F (-40 to 85°C); Relative humidity: 0 to 90% non-condensing
ConnectionsRemovable and integrated screw terminal blocks accept 12 to 22 AWG wire.
EnclosureUL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
Wall MountingFour (4) mounting holes provided for mounting meter to wall.
Pipe MountingOptional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately.
See PD2-6310 manual for instructions.
Tightening TorqueRemovable Screw Terminals: 5 lb-in (0.56 Nm)
Digital I/O and RS485 Terminals2.2 lb-in (0.25 Nm)
Overall Dimensions (H x W x D)10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm)
Weight6.10 lbs (2.76 kg)
UL File NumberUL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB ConnectionCompatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty3 years parts & labor
  • Thumbnail of document Data Sheet - PD2-6310 Helios Pulse Input Batch Controller
    Download

    Data Sheet - PD2-6310 Helios Pulse Input Batch Controller

    Download
  • Thumbnail of document Manual - PD2-6310 Helios Pulse Input Batch Controller
    Download

    Manual - PD2-6310 Helios Pulse Input Batch Controller

    Download
  • Thumbnail of document Software - PD2-6310 Helios Pulse Input Batch Controller
    Download

    Software - PD2-6310 Helios Pulse Input Batch Controller

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more