Skip to main content
Press Enter
Buy now! $1,020.00CAD
Precision Digital

PD6088 ProVu Decimal Display Modbus Scanner

Decimal display, displays up to 16 Modbus process variables (PVs) on the bus using its RS-485 serial input

Buy now!
$1,020.00CAD
Have questions? We're here to help!
Have questions? We're here to help!

The ProVu PD6088 Super Snooper Modbus® scanner displays up to 16 Modbus process variables (PVs) on the bus using its RS-485 serial input. The PD6088 can function as a Modbus master, slave, or snooper. As a Modbus master, the PD6088 can poll multiple Modbus devices for up to 16 Modbus process variables. As a slave, a Modbus master can write up to 16 PVs to the scanner for display. In snooper mode, it can sit anywhere on the Modbus network and display up to 16 PVs being polled on the bus. When connecting a scanner in snooper mode, no other Modbus devices on the network need to be reconfigured, making it easy to add additional local or remote displays to a Modbus network. Like all ProVu meters, the PD6088 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

     
 

• Modbus® RS-485 RTU Serial Communications as Master, Slave, or Snooper
• RS-485 Serial Communications Standard
• Scan up to 16 Modbus Process Variables
• Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, & More
• Large Dual-Line 6-Digit Display, 0.60" & 0.46"
• SunBright Display Standard
• NEMA 4X, IP65 Front
• Universal 85-265 VAC, or 12/24 VDC Input Power Models
• Onboard USB and ScanView Programming Software

Input/OutputModbus RTU over RS-485
DisplayUpper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs
Display IntensityEight user selectable intensity levels
Display Scan RateMaster/Snooper: 1/second to once every 99.9 seconds. Slave: Dependent on master device (e.g. PLC)
Over RangeDisplay flashes 999999
Under RangeDisplay flashes -99999
Display AssignmentThe top display may be assigned to PV (process values), Ch C (math channel), PV & units, tag & PV, tag-PV-units, C & units, tag-C-unit, Set point 1-8, max/min PV, max/min C. The bottom display may be assigned to all of the above, tag, or off. The tag and units are displayed alternately for 2 sec, when selected. Different tags & PVs may be selected to display on the top and bottom displays at the same time.
Front PanelNEMA 4X, IP65
Programming MethodsFour front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
F4 Digital Input Contacts3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic LevelsLogic High: 3 to 5 VDC
Noise filterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationAll ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
PasswordThree programmable passwords restrict modification of programmed settings.
Non-Volatile MemoryAll programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental Operating temperature range: -40 to 65°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
Max Power DissipationPD8 Series: Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
Tightening TorqueScrew terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions (W x H x D)4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
Weight9.5 oz (269 g)
UL File NumberUL & c-UL Listed. E160849; 508 Industrial Control Equipment.
USB ConnectionCompatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty3 years parts & labor
  • Thumbnail of document Data Sheet - PD6088 ProVu Decimal Display Modbus Scanner
    Download

    Data Sheet - PD6088 ProVu Decimal Display Modbus Scanner

    Download
  • Thumbnail of document Manual - PD6088 ProVu Decimal Display Modbus Scanner
    Download

    Manual - PD6088 ProVu Decimal Display Modbus Scanner

    Download
  • Thumbnail of document Software - PD6088 ProVu Decimal Display Modbus Scanner
    Download

    Software - PD6088 ProVu Decimal Display Modbus Scanner

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more