PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner

Offers all functionality of the PD6080, approved exlposion-proof, scans up to 16 Modbus variables, dual analog inputs

Starting at
$2,697.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The ProtEX-MAX™ PD8-6080 Super Snooper Modbus® scanner offers all the functionality of the ProVu PD6080 as a fully FM, CSA, ATEX, and IECEx approved explosion-proof product. It is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and includes dual analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of a conveniently located display in a hazardous area. The PD8-6080 includes a 24 VDC power supply to drive the transmitter and can be equipped with up to four internal relays and two 4-20 mA outputs. It can be programmed and operated without opening the housing by using the built-in SafeTouch® through-glass buttons.


               

Quick Overview

• Input: Modbus with five-wire RS-485 for up to 16 Modbus process variables; two analog inputs, each separately field selectable; 0-20 mA, 4-20 mA; ±10 VDC (0-5, 1-5, 0-10 V); Modbus PV (slave)
• Display: Dual-line 6-digit, 0.60" (15 mm) & 0.46" (12 mm)
• Case: Smooth die-cast aluminum explosion-proof
• Power: 85-265 VAC or 12-24 VDC option
• Operating Temperature: -40 to 65°C

• SunBright Display Standard
• Modbus RTU master, slave, or snooper mode with RS-485 serial communications
• Master mode can scan up to 16 Modbus PVs from Modbus transmitters
• Snooper mode can scan up to 16 Modbus PVs polled by a different Modbus master
• Up to Four Math Channels for Addition, Difference, Average, Ratio & More
• SafeTouch® through-glass button programming
• Isolated 24 VDC @ 25 mA transmitter power supply
• 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs
• Onboard USB and ScanView programming software

Input/OutputModbus RTU over RS-485, Two analog inputs (4-20 mA, ±10 V)
DisplayUpper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs
Display IntensityEight user selectable intensity levels
Display Scan RateMaster/Snooper: 1/second to once every 99.9 seconds. Slave: Dependent on master device (e.g. PLC)
Over RangeDisplay flashes 999999
Under RangeDisplay flashes -99999
Display AssignmentThe top display may be assigned to PV (process values), Ch C (math channel), PV & units, tag & PV, tag-PV-units, C & units, tag-C-unit, Set point 1-8, max/min PV, max/min C. The bottom display may be assigned to all of the above, tag, or off. The tag and units are displayed alternately for 2 sec, when selected. Different tags & PVs may be selected to display on the top and bottom displays at the same time.
Programming MethodsFour through-glass SafeTouch buttons, four mechanical buttons behind glass, digital inputs, PC and ScanView software, or Modbus registers.
F4 Digital Input Contacts3.3 VDC on contact. Connect normally open contacts across F4 to COM.
F4 Digital Input Logic LevelsLogic High: 3 to 5 VDC; Logic Low: 0 to 1.25 VDC
Noise filterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationAll ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min DisplayMax (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
PasswordThree programmable passwords restrict modification of programmed settings.
Non-Volatile MemoryAll programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or optional model with 12-24 VDC ±10%, 15 W max.
FuseRequired external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Isolated Transmitter Power SupplyTerminals P+ & P-: 24 VDC ± 10%. Isolated from the input at >500 V. Jumper selectable for 24, 10, or 5 VDC supply (internal jumper J4). All models transmitter supply rated @ 25mA max.
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
Overvoltage CategoryInstallation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
EnvironmentalT6 Class operating temperature range Ta = -40 to 60°C
T5 Class operating temperature range Ta = -40 to 65°C
Max Power DissipationMaximum power dissipation limited to 15.1 W.
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
EnclosureExplosion-proof die cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Default conduit connections: Four ¾" NPT threaded conduit openings and two ¾" NPT metal conduit plugs with 12 mm hex key fitting installed. Additional conduit opening configurations may be available; verify quantity and sizes on specific device labeling during installation.
MountingFour slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting.
Dimensions (W x H x D)6.42" x 7.97" x 8.47" (163 mm x 202 mm x 215 mm)
Weight16.0 lbs (7.26 kg)
USB ConnectionCompatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
Warranty3 years parts & labor
  • Thumbnail of document Data Sheet - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner
    Download

    Data Sheet - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner

    Download
  • Thumbnail of document Manual - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner
    Download

    Manual - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner

    Download
  • Thumbnail of document Software - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner
    Download

    Software - PD8-6080 ProtEX-MAX Explosion-Proof Modbus Scanner

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more