The ConsoliDator+ is a multivariable controller that is both easy to use and satisfies a wide variety of process display, alarm, and control applications. It accepts 4-20 mA inputs, flow meter pulse inputs, digital inputs, and Modbus inputs and displays them in both numeric and bargraph format on a large, 5.7" color display. It can be equipped with multiple relays with userdefinable actions, 4-20 mA outputs, digital outputs, Modbus RTU & ASCII, Modbus Enron, and Ethernet Modbus TCP/ IP protocol communication. Additionally, the controller is equipped with up to 30 timers that can be used to control many processes or events. Two standard new features have been added to the version 2.300 release: • Auto-Tune PID Control • Digital Switches (HOA) The ConsoliDator+ takes full advantage of its color display by allowing the user to customize screen colors for bargraphs, alarm conditions, and input channels. All this functionality is easily programmed using the free software or via the front panel pushbuttons. Choose the model that best suits your application, from monitoring only to fully loaded controllers with an extensive combination of inputs, outputs, and communication protocols. The standard product offering is listed in the ordering guide and other models are available for special order. The Add-On features expand the functionality of the ConsoliDator+, see the next page for details. The ConsoliDator+ has been Certified by Underwriters Laboratory (UL & C-UL) for use in ordinary locations (electrical safety) and in Div 2 hazardous area locations (nonincendive).

 

• NEMA 4X Panel Mount Multivariable Controller 
• Convenient Display, Control, & Alarm of Multiple 4-20 mA, Pulse, & Modbus Inputs 
• Numeric & Bargraph Color Display (320 x 240 pixels) 5.7" (145 mm) 
• Sunlight Readable Display, White Backlight 
• Isolated 24 VDC Transmitter Supplies 200 mA / Analog Input: 1,600 mA Max 
• 99 Channels, 32 Totalizers, 30 Timers, & 199 Modbus Inputs 
• 64 High & Low Alarms, Combine Multiple Alarms Into Logic AND & OR Alarms 
• Simulation & Manual Control Modes for Testing and Setup 
• Modular Design for Inputs & Outputs Flexibility 
• Up to (28) 4-20 mA Isolated Inputs or Pulse Inputs 
• Up to (25) 10 Amp Form C Relays (With Eight Analog or Pulse Inputs) 
• Up to (25) Isolated 4-20 mA Outputs (With Eight Analog or Pulse Inputs) 
• Operating Temperature Range: -25°C to 55°C (-13 to 131°F) 
• Pulse, Analog, & Modbus Input Flow Rate / Total / Grand Total Capability 
• 50-Point Linearization, Square Root, and Exponent for Open Channel Flow 
• Round Horizontal Tank Volume Calculation; Just Enter Diameter & Length 
• Open Channel Flow Math Formulas for Weirs & Flumes 
• Multi-Pump Alternation Control or On / Off Control with Random Varying Set Point 
• Programmable Displays, Function Keys & Digital Inputs
 • Math Functions: Sum, Diff, Average, Multiply, Divide, % Efficiency, & More 
• Modbus Client (Master) & Snooper / Server with 99 Programmable Outputs 
• Direct Modbus PV Inputs – Snooper / Server Mode 
• Modbus Spoofer Feature to Replace Servers Removed from Network 
• RS-485 Serial Communication with Modbus RTU / ASCII & Ethernet TCP/IP 
• USB Data Logger Feature: Up to 8 Log Files with up to 12 Parameters Each 
• Input Power Options: 90-264 VAC or 24 VDC 
• (20) Screens with up to Eight PVs Each 
• ConsoliDator+ Configuration Software 
• Type 4X, IP66 Front – Field Enclosures Available 
• Auto-Tune PID Control for Multiple Control Loops 
• PID Control with Analog, Digital, or Relay Outputs 
• Digital Selector Switch (HOA) Function to Route Inputs & Outputs 
• 3-Year Warranty w
Tightening TorqueScrew terminal connectors: 5 lb-in (0.56 Nm)
Digital I/O terminals: 2.5 lb-in (0.28 Nm)
EnclosureEnclosure Body: Thermoplastic Polyester, Color: Gray, Display Window: Clear Polycarbonate, GE LEXAN HP12W, Front Panel Keys: Silicone rubber
Tamper Proof EnclosureThe field mount enclosure's cover is secured by a clasp that can be locked to prevent unauthorized access to the enclosure's interior.
Mounting: Wall-MountFour screws/bolts required (not provided)
Pipe-Mount: (2) U-Bolts for 2" Pipe (See Ordering Information)
Panel-Mount: Panel-mounting frame and twelve screws (provided)
Cutout: 10.0" x 10.0" ±0.05" (254 mm x 254 mm ±1.3 mm) (H x W)
Panel thickness: 0.07" – 0.35" (1.8 mm – 8.9 mm)
Clearance behind panel: 6" (152 mm)
Conduit ConnectionsThere are four center punched marks on each side of the field enclosure. Holes must be drilled by the installer according to the desired conduit entry. Size: ½" or ¾" (16 mm or 21 mm),
Clearance: 1.5" (38 mm) diameter
Overall DimensionsPanel-Mount: 10.85" x 10.85" x 4.87" (276 mm x 276 mm x 124 mm) (H x W x D)
Field-Mount: 11.5" x 12.0" x 8.03" (292 mm x 305 mm x 204 mm) (H x W x D)
WeightEx: PD9000-XY-4PI-8AI-10AO-10RY
Panel-Mount: 7.4 lb (3.4 kg) approx.
Field-Mount: 10.8 lb (4.9 kg) approx.
Warranty3 years parts and labor
DisplayColor; QVGA (320x240 px), 5.7" (145 mm) diagonally, white backlight Bargraph: Twenty divisions Numerical: Up to 15 digits (±999,999,999,999,999) Feet & Inches Format: 99,999' 11.9"
Screen BargraphEnable/disable: Channels, totals, timers Bargraph scale: 0 – 100%, independent of channel scale. Twenty divisions: 5% each. Screen: Select to show bargraph or not.
Decimal Point0 to 15 decimal places, user selectable
Engineering UnitsUser selectable units or custom units Time, Distance, Volume, Pressure, Weight, Temperature, Current, Voltage, Percent, Amps, Volts, Counts, Logic, and Custom, Any unit/unit of time or other units
Display Update RateUser selectable: 0.1 to 10 sec (10 updates/sec to 1 update/10 sec)
Programming MethodFront panel buttons, external buttons, or ConsoliDator+ Software
Number of AlarmsUp to 64 high or low Automatic (non-latching) or latching On & Off time delays. May be assigned to one or more relays. Note: Alarms are independent from relays.
Alarm TypesSingle Source: One input
Multi-Source: Two or more inputs
Interval: Enter time interval and On Time
Alarm OR: Any active input alarm triggers the OR alarm
Alarm AND: All input alarms must be active to trigger the AND alarm
Alarm Ack & ResetAutomatic only (Non-latching)
Automatic and manual
Manual only (Latching)
Manual with Ack only after alarm is cleared (Latching with Clear)
Internal Buzzer60 dBA @ 24 inches (61 cm) Enable/disable in System – General menu. Associated with alarm Horn setting
External Horn (Sold separately)Assign any relay to the Horn function to activate an external horn when alarm condition is detected.
Input & Output CardsMax Number of I/O Cards: 7, Analog Inputs: 4/card, Pulse Inputs: 4/card, Analog Outputs: 5/card, Relays: 5/card
Number of ScreensUp to 20 screens with 1 to 8 PVs or items per screen. Enable or disable screen title, channel #, and bargraph Automatic or manual scanning Scan time: 1 to >1000 sec, independent for each screen. F1-F4 keys are assigned per screen
Function KeysUser programmable (See defaults below) F1 = Previous ← F2 = Next → F3 = Scan/Stop F4 = Ack
Number of ChannelsUp to 99 channels, Input source: 4-20 mA, Pulse, Digital, Modbus, Alarm, or Math
PasswordProgrammable password restricts modification of programmed settings
Non-Volatile MemorySettings stored for a minimum of 10 years
Power (User Selectable Based on Wiring)Three-terminal connector (L, N, GND), AC: 80-264 VAC, 47 to 63 Hz, 60 W max DC: 113-370 VDC, 60 W max (L, N), Two-terminal connector (G, 24V) DC: 24 VDC ±10%, 60 W max
Backup Power SupplyIf AC and DC power are connected, the 24 VDC can be used as backup power in case of AC power failure.
FuseUnit is protected internally with auto-resettable fuse. AC: 1.25 A max, DC: 3.7 A max
External FuseRecommended external fuse slow-blow 120 VAC: 2.0 A, 240 VAC: 1.0 A, 24 VDC: 4 A
Isolation & Grounding1500 V Analog inputs/outputs-to-power line
500 V Analog input-to-input, input-to-output, analog output-to-output
All analog inputs and analog outputs are isolated from each other.
Note: DC Power is not isolated. DC- is connected to Earth Ground. Digital I/O, USB, and Ethernet are grounded.
EnvironmentalOperating temperature range: -40 to 60°C (-40 to 140°F)
Storage temperature range: -40 to 60°C (-40 to 140°F)
Relative humidity: 0 to 90% non-condensing
*All functions operate down to -40°C (-40°F.) If the LCD response is slower, increase the display refresh setting.
ConnectionsRemovable screw terminal blocks, Inputs/Outputs: 12 to 24 AWG wire, Digital I/O: 16 to 30 AWG, RS-485: 12 to 24 AWG wire RJ45 Ethernet connection. USB ports: Micro-USB (Device) and Type A (Host)

  • Thumbnail of document Manual - PD9000 ConsoliDator+ Multivariable Controller
    Download

    Manual - PD9000 ConsoliDator+ Multivariable Controller

    Download
  • Thumbnail of document Data Sheet - PD9000 ConsoliDator+ Multivariable Controller
    Download

    Data Sheet - PD9000 ConsoliDator+ Multivariable Controller

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more