Skip to main content
Press Enter
OMEGA

PX3005-160WDWBI Rangeable, Differential Press. Transmitters w/Display

-160 to 160 inH2O, Differential Pressure

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!
Configure

Supported Applications

The Omega PX3005-DIFF is a rangeable differential pressure transmitter designed for process automation, hydraulic systems, compressors, pumps, and tank level applications. The series utilizes an encapsulated MEMS piezoresistive sensor coupled with advanced microprocessing to monitor pressures in environments requiring consistent measurement of fluids and gases compatible with 316 SS.

Operating Conditions & Performance

The PX3005-DIFF operates within a process temperature range of -40 to 120°C (-40 to 250°F) and an ambient operating temperature of -20 to 70°C (-4 to 160°F). Storage is supported from -40 to 85°C. The transmitter features a rugged 316 SS enclosure with an IP67 environmental rating, suitable for wash-down environments.

Performance specifications include an accuracy of ±0.075TD% SPAN (NLHR, 20°C ±5°C) for linear output; square root output accuracy is 1.5 times the linear output accuracy. Long-term stability is rated at ±0.2% URL/60 months. The sensor response time is 200 mS with selectable damping from 0 to 100 S.

Static pressure limits are defined by range: for ranges up to 400 Mbar, the limit is 400 Bar; specific over-range limits vary by model. The series supports a power supply of 10.5 to 55VDC with a load resistance calculated as <(U-10.5)/0.021 Ω.

Measurement Ranges

The documented differential pressure ranges include:

• -25 to 25 inH2O (PX3005-25WDWBI)
• -160 to 160 inH2O (PX3005-160WDWBI)
• -1,000 to 1,000 inH2O (PX3005-1KWDWBI)
• -70 to 150 psi (PX3005-150DWBI)
• -70 to 400 psi (PX3005-400DWBI)
• -70 to 1,500 psi (PX3005-1.5KDWBI)

Rangeability allows adjustment of zero and span from -100 to 100% FS URL with a minimum span of 30% URL.

Configuration Options

The series offers configurable output signals, display options, and process connections tailored to specific installation needs. The intelligent transmitter module supports configuration via a 5-digit backlit LCD for full precision representation of the process variable.

Outputs & Signals

• Output Signal: 4 to 20mA Two wire, linear or square root output selectable.
• Electrical Connection: 4 pin male M12 connector (wiring: Brown/Power+, White/Signal+, Blue/Signal-, Black/Power-).

Housing & Materials

• Housing Material: 316 SS.
• Isolating Diaphragm: 316L SS.
• Sensor Fill Fluid: Silicone Oil.
• Sensor Seal: O-ring, FKM.

Process Connections & Mounting

• Standard Connection: ¼" -18NPT F/316 SS.
• Mounting Options: The series supports bracket installation options including pipe mounting bent, plate mounting bent, and pipe mounting flat configurations (per family manual).

Key Product Differences

The PX3005-DIFF series is distinguished by its specific pressure ranges and model numbering. The available variants cover low differential pressures in inches of water column (-25 to 1,000 inH2O) and higher differential pressures in psi (-70 to 1,500 psi). All listed models feature the "DWBI" suffix indicating a display module with specific wiring configurations.

Technical distinctions include:

• PX3005-25WDWBI: -25 to 25 inH2O differential range.
• PX3005-160WDWBI: -160 to 160 inH2O differential range.
• PX3005-1KWDWBI: -1,000 to 1,000 inH2O differential range.
• PX3005-150DWBI: -70 to 150 psi differential range.
• PX3005-400DWBI: -70 to 400 psi differential range.
• PX3005-1.5KDWBI: -70 to 1,500 psi differential range.

• 0.075% Accuracy
• Linear or Square Root Output
• Adjustable Pulsation Dampening
• LCD Displays Either Process Variable, mA, or %
Accuracy± 0.075 %
Accuracy Class< 0.1%
Accuracy DetailAccuracy (NLHR, 20°C ± 5°C): ± 0.075TD% SPAN (Square root output accuracy is 1.5 times linear output accuracy)
Additional Features 1Rangable with 5 digit display
Damping Time0 to 100 sec
Electrical ConnectionM12 4 pin
Electrical Output4 to 20 mA
Electrical Output Note4 to 20mA Two wire, linear or square root output selectable
Enclosure Material316L Stainless Steel
Enclosure RatingsIP67
Fill FluidSilicon oil
Loop Resistance, Max<(U-10.5)/0.021Ω, where U is supply voltage
Operating Temperature, Max70 °C
Operating Temperature, Min-20 °C
Output SignalCurrent
Position EffectInstall error less than 400Pa (1.60” H2O) can be corrected by PV = 0 reset
Power Supply500 mW
Measurement Pressure TypeDifferential
Process Connection Size1/4 in
Process Connection TypeNPT Female
Process Temperature, Max120 °C
Process Temperature, Min-40 °C
Response Time200 ms
Series IDPX3005-DIFF
Stability± 0.2%
Stability Note± 0.2% 60 months
Storage Temperature, Max85 °C
Storage Temperature, Min-40 °C
Supply Voltage10.5 to 55 Vdc
Thermal Effect on Zero error, Max± (0.1 +0.1TD)% SPAN
Transmission Distanceup to 1000 meters
Vibration EffectGB/T 1827.3/IEC61298-3 tests, 20g (5 to 2000 HZ, max <± 3 mm), <0.1% URL
Weight3 kg
  • Download

    Data Sheet - PX3005-160WDWBI Rangeable, Differential Press. Transmitters w/Display

    Download
  • Download

    Manual - PX3005-160WDWBI Rangeable, Differential Press. Transmitters w/Display

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more