PX509-015AC2IS High Accuracy, Intrinsically Safe Press. Transmitters

0 to 15 psi, Absolute , Cable

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The PX509-IS series delivers intrinsically safe pressure measurement for hazardous locations where high accuracy and long-term stability are essential. With 316L stainless steel wetted parts standard and welded stainless steel construction, the transmitters are built for rugged industrial service.

• Process Control
• Hydraulic and Pneumatic Systems
• Natural Gas Compressors
• Chemical Refineries
• Oil and Gas
• Pipeline Measurements
• Hydrogen (316L SS Wetted Parts Standard)
• Power Generation

The series carries FM Intrinsically Safe approval for Class I, II, III, Division 1 Gr A, B, C, D, E, F, G, and Class I, Zone 0 Aex ia IIC (US) / Ex ia IIC (Canada). An FM Non-Incendive rating covers Class I Division 2 Groups A, B, C, D (US and Canada) for conduit electrical connections only. Every unit ships with a NIST Traceable Calibration Certificate.

Operating Conditions & Performance

The PX509-IS operates across an ambient temperature of -40 to 75°C. Accuracy is specified at ±0.08% BSL maximum for the combined effect of linearity, hysteresis and repeatability, with long term (1-year) stability of ±0.1% full scale typical and a response time of <1 msec.

• Excitation: 10 to 28 Vdc
• Output: 4 to 20 mA
• Enclosure rating: IP65
• Vibration: ±20 g
• Shock: 50 g, 11 msec half sine shock
• Weight: 315 g typical

Measurement ranges span 10 inH2O to 3500 psi across gage, sealed gage, absolute, compound gage, vacuum and barometric configurations. Units are rated for 1 million pressure cycles typical, and containment reaches up to 11,000 psi on the highest ranges. Standard process connections are ¼-18 NPT male and G1/4B male.

Configuration Options

Models in the series differ primarily by electrical termination and environmental sealing, letting you match the sensor to the wiring method and installation constraints of the application. All terminations are rated IP65.

• PX509 uses cable with flying leads, 2 m (6').
• PX509C adds a ½ NPT conduit connector but has no trim pots and is not demountable.
• PX509CP provides a ½ NPT conduit connector with side accessible trim pots.
• PX509CW and PX509CWP are submersible versions with a ½ NPT conduit connector and a 3 m (10') cable.
• PX519, PX529, PX539, PX549 and PX559 replace the cable with mini-DIN, twist-lock 6 pin, DIN, glass-to-metal sealed solder pins, and M12 connectors respectively.

Metric-calibrated versions are offered under the PXM5 designation for applications specified in bar and mbar. Models with the ½ NPT conduit fitting (PX509C) do not have a demountable termination, and trim pots are an extra cost option.

Key Product Differences

The electrical termination code selects the base model:

• PX509 — Cable with flying leads, 2 m (6')
• PX509C — Cable with ½ NPT conduit connector (no trim pots, not demountable)
• PX509CP — Cable with ½ NPT conduit connector and side accessible trim pots
• PX509CW — Submersible cable with ½ NPT conduit connector, 3 m (10')
• PX509CWP — Submersible cable with ½ NPT conduit connector and side accessible trim pots, 3 m (10')
• PX519 — mini-DIN connector (mating connector not included)
• PX529 — Twist-lock 6 pin connector
• PX539 — DIN connector (mating connector not included)
• PX549 — Glass to metal sealed solder pins
• PX559 — M12 connector, M12 cables sold separately

• High 0.08% Accuracy with NIST Traceable Calibration Certificate
• 4 to 20 mA Output with FM Intrinsically Safe Rating
• Solid State Sensor for Long Term Stability
• 316L SS Wetted Parts and Welded Stainless Steel Construction
Accuracy± 0.08 %
Accuracy Class< 0.1%
Accuracy Detail± 0.08% BSL maximum (other accuracies available) For conduit (C and CW) zero and span set ± 0.5% full scale typical ± 1% maximum or set ± 1% full scale typical ± 2% maximum ranges 2.5 psi and below
BandwidthDC to 1 kHz
Cable Length10 ft
Compensated Temperature, Max75 °C
Electrical Output4 to 20 mA
Insulation Resistance100 MΩ @ 50 Vdc
Operating Temperature, Min-40 °C
Pressure Cycles1 million, minimum
Process Connection Size1/4 in
Process Connection TypeNPT Male
Proof PressureUp to 1000 psi
Response Time<1 ms
Sensing ElementOil filled Piezoresistive MEMS
Series IDPX509-IS
Shock50 g, 11 ms half-sine
Stability± 0.1%
Vibration± 20 g
Weight315 g
  • Download

    Data Sheet - PX509-015AC2IS High Accuracy, Intrinsically Safe Press. Transmitters

    Download
  • Download

    Manual - PX509-015AC2IS High Accuracy, Intrinsically Safe Press. Transmitters

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more