The Sludge Finder 2 provides reliable and continuous sludge blanket level measurement. The two-part system has been purposely designed for sludge blanket level measurement, operating ultrasonically through a liquid. The Sludge Finder 2 uses proven echo processing algorithms to identify the sludge interface level using state of the art technology only found in this unit!
 
Sludge blanket level control is a crucial aspect of any process that includes primary settlement tanks, secondary settlement tanks, tertiary settlement tanks either with stationary or traveling bridges, clarifiers, gravity thickeners, or sequencing batch reactor systems. Sludge blanket level measurement works by measuring the distance between the sludge blanket surface and the water level. Once the sludge has reached the required density, the accompanying controller will then switch on the pumps and pump the sludge through into digesters, ready for the next treatment stage.
 
Effective sludge blanket level measurement can help treatment plants or industrial processes to generate their own electricity, ensure that pumps are being used efficiently, ensure that excess sludge is not being pumped into our local water sources, aids with compliance to health, safety, and environmental regulations, and finally, ensures that further sludge handling processes such as thickeners and dewatering equipment are all performing to their maximum with the correct concentration of sludge.
• Continuous single or dual-channel level control
• High-frequency gives high-reliability long term
• Self-cleaning transducer removes the need for regular inspection
• SBR tank applications can be monitored
• Easy set-up via the drop-down menu on large clear display
• The unit can track two different echoes with one transducer
• Radio telemetry system - optional
Weight1 kg (2.2 lbs)
Cable entry details10 cable entry knockouts, 5 x M20, and 1 x M16 underside. 4 x PG11 at rear
Analog Operating Temperature (Electronics)-20 °C to +50 °C (-4 °F to +122 °F)
Analog output2 x isolated (to 150 V floating) output of 4-20mA or 0-20mA into 1 kΩ (user-programmable and adjustable) 0.1% resolution
Digital outputHalf-duplex RS232
Display192 x 128 pixel illuminated graphical display showing a variety of screens including echo profile. Fully programmable display options, integral keypad with menu navigation keys
PC SoftwareSludge Finder PC within PC Software Suite - compatible with XP (service pack 3), Windows 7/8/10
Fuse 2 A slow blow
Operating VoltageUniversal 100-240 V AC 50/60 Hz, 22-28 V DC
Power Consumption20 W maximum power (typically 11 W)
Viper Sensor Specifications
Sensor body dimensions78 mm x 195 mm (3.07 in x 7.67 in)
Sensor body weightNominal 1.5 kg (3.3 lbs)
Sensor body materialValox 357
Wiper blade - Stainless steel
Transducer cable extensions4-core screened
Minimum sludge density0.5% concentration
Maximum separation200 m (656 ft)
Enclosure protectionIP68
Accuracy0.25% of the measured range or 10 mm (0.39 in); whichever is greater
Resolution0.25% of the measured range or 10 mm (0.39 in); whichever is greater
Max range 10 m (32.8 ft)
Min range0.3 m (0.98 ft)
  • Thumbnail of document Data Sheet - Sludge Finder 2 Blanket Level Control
    Download

    Data Sheet - Sludge Finder 2 Blanket Level Control

    Download
  • Thumbnail of document Manual - Sludge Finder 2 Blanket Level Control
    Download

    Manual - Sludge Finder 2 Blanket Level Control

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more