Skip to main content
Press Enter
Buy now! $1,320.00CAD
ACR Systems

SRX2 Smart Reader

Self-powered, multi-channel data logger effortlessly and accurately logs and records temperature and relative humidity data

Buy now!
$1,320.00CAD
Have questions? We're here to help!
Have questions? We're here to help!


Designed for Reliable, Long-Term Temperature and Humidity Monitoring
The SRX2 is purpose-built for applications where accurate temperature and relative humidity data must be collected over long periods with minimal maintenance. It combines onboard temperature and RH sensing with support for one optional remote temperature and RH probe, allowing conditions to be monitored in two locations simultaneously—such as ambient room conditions and the interior of a duct, enclosure, or storage space.

Relative humidity is measured over a full 0–100 %RH range with ±3 %RH accuracy, providing dependable data for building monitoring, environmental diagnostics, pharmaceutical storage, and general facility applications. A wide operating temperature range of −40°C to +85°C supports use in both indoor and demanding environments.

Built for Extended Deployments
SRX2 is designed for unattended operation. A typical battery life of up to 10 years under normal operating conditions minimizes servicing requirements, while a 1 million reading onboard memory supports long deployments even at relatively short sample intervals. Flexible logging modes allow users to tailor data collection to the application, whether monitoring slow environmental changes or capturing shorter-term events.

Alarm thresholds can be configured to flag out-of-range conditions, providing visual indication and recorded events that help users quickly identify excursions or system issues.

Optional Expansion Beyond Temperature and Humidity
While SRX2 is first and foremost a temperature and humidity logger, it also includes additional analog input channels for applications that require more advanced measurements. These include two 4–20 mA current inputs, as well as dedicated 0–5 V and 0–10 V DC inputs, enabling connection to common transmitters such as pressure, airflow, or level sensors when needed.

These optional inputs allow environmental data to be correlated with system or process signals, without changing the core role of the logger.

Data Analysis and Reporting with TRX Software
SRX2 is configured, downloaded, and analyzed using ACR’s TRX Software for Windows. TRX provides an intuitive interface for graphing temperature, humidity, and analog input data on a shared time axis, allowing users to zoom into events, review trends, and generate reports for documentation or record keeping. Data can be exported to common file formats for further analysis or archiving.

  • Capable of storing up to 1 million readings
  • LED flashing alarm lights
  • Two-stage alarming (Warning & Critical)
  • 16-bit resolution provides greater precision
  • Can be calibrated to NIST standards to achieve the highest possible measurement accuracy
  • Portable equations onboard the data logger ensure faster downloads and collaboration with less user intervntion
  • One-button report generation
  • Wizards for Equations and programming for ease of use
Alarm ConnectorCritical and Warning connections Maximum 15V Maximum 350mA
Battery3.6V Lithium Typical battery life: 10 years under normal operating conditions @ 25°C
Channel 0 - Internal TempResolution: 0.01°C Range: -40°C - 85°C Accuracy: ± 0.3°C
Channel 1 & 2 DC CurrentInput Impedance: 10 ohms Resolution: 16-bit Range: 0 – 25mA DC Accuracy: ± 0.5% Full Scale
Channel 3 – DC VoltageInput Impedance: ~ 1 Megohm Resolution: 16-bit Range: 0 – 5V DC Accuracy: ± 0.5% Full Scale
Channel 4 – DC VoltageInput Impedance: ~ 1 Megohm Resolution: 16-bit Range: 0 – 10V DC Accuracy: ± 0.5% Full Scale
Channel 5 – Internal Sensor RHResolution: 0.01 %RH Range: 0 – 100 %RH Accuracy: ± 3 %RH
Channel 6 - for external probeTypical: EH-030 Temperature channel
Channel 7 - for external probeTypical: EH-030 RH channel
Clock Accuracy± 1 seconds per day
LED Status & Alarm LightsHigh & Low thresholds per channel Latch / Self-reset
Memory Size1 Million Readings
Operating Limits-40°C to 85°C (-40°F to 185°F) 0 to 95% RH non-condensing
Sample Rates1 minute to 24 hours
Sampling MethodsContinuous (first-in-first-out) / Stop when full Immediate start / Delayed start - up to 2 months Spot / Averaged Readings
Size111 mm (4 3/8") x 74mm (2 15/16") x 27 mm (1 1/16")
Status IndicatorFlash rate: 10 seconds Green: logging Blue: delayed start Yellow: alarm warning Red: critical alarm Magenta: memory full
Warranty3 Years
Weight140g (5 oz)
  • Building power monitoring
  • HVAC systems testing & balancing
  • Pharmaceutical manufacturing & storage
  • Storage conditions of perishable items
  • Building comfort monitoring
  • Plug load equipment monitoring
  • Lighting systems monitoring
  • Download

    SRX2 Product Data Sheet

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more