Skip to main content
Press Enter
OMEGA

TXUN-FD Field Mounted Hart Protocol Temp. Transmitter

Field Mounted Hart Protocol Enabled Temperature Transmitter

Have questions? We're here to help!
Have questions? We're here to help!

 High Definition Display

• 0, 90, 180, & 270 degree position adjustments.
• Monitoring, programming, and diagnostics view.
• Extensive diagnostics with flashing red or white backlight
• Supports 7 languages
Local operator interface (LOI)
• 3 optical buttons up, down and enter.
• Dynamically adaptive to wear or accumulation of dirt.
• Immune to interference from ambient light sources.
• Useable with or without gloves.
Configuration
• From the LOI through guided user menu.
• OMSET and HART modem.
• HHC, DCS or AMS via HART.
Mounting/Installation
• For installation in zone 0, 1, 2 and zone 20, 21, 22 and in Class 1, Division 1 and 2 applications.
• Hardware assessed for use in SIL 2 applications.
• Mounting on 1.5”–2” pipe bracket or on wall / bulkhead.
Application
• Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
• HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
• Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
• Amplification of bipolar mV signals to standard 4...20 mA current signals.
• Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
Technical Characteristics
• NAMUR NE43 and NE89.
• HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
• RTD, TC, Ω, and Bipolar mV Input and Analog Output
• High Definition Local Operator Interface (LOI) with 3 Optical Buttons
• Selectable Red or White Backlight
• Ex D Explosion Proof/Flame Proof in Aluminum or 316 Stainless Steel Version
Operating Temperature-40 to 85°C (with silicone O-ring)
Environmental Conditions
SILHardware assessed for use in SIL applications
NEPSIGYJ15.1336X, GYJ15.1337X and GYJ15.1338X
INMETRODEKRA 15.0014 X
EAC Ex TR-CU 012/2011RU C-DK.GB08.V.01316
CSA70024231
FMFM16US0009X/FM16CA0010X
IECExIECEx DEK 15.0039 X
ATEX 2014/34/EUDEKRA 15 ATEX 0058 X
ApprovalMRA0000009
EU RO Mutual Recognition Type
Approvals
EACTR-CU 020/2011
EMC2014/30/EU
Observed Authority Requirements
HART Protocol RevisionsHART 7 and HART 5
Updating Time440 ms
Common Output Specifications
NAMUR NE43 Upscale/Downscale23 mA/3.5 mA
Sensor Error Indication:Programmable 3.5 to 23 mA
Load Resistance, with Backlight≤ (Vsupply - 12) / 0.023 [Ω]
Load (@ Current Output)≤ (Vsupply - 10) / 0.023 [Ω]
Min. Signal Range6 mA
Signal Range4 to 20 mA
Current Output
Output Specifications
Input Resistance10 MΩ
Min. Measurement Range (Span)2.5 mV
Measurement Range800 to 800 mV
Voltage input
Cold Junction Compensation (CJC)Constant, internal or external via a Pt100 or Ni100 sensor
Thermocouple TypeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
TC Input
Linear Resistance Min/Max0 to 7000 Ω
Linear Resistance Input
Sensor CurrentNom. 0.2 mA
Cable Resistance per Wire5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
RTD TypePt50/100/200/500/1000 Ni50/100/120/1000
RTD Input
Max. Offset50% of selected max. value
Common Input Specifications
Input Specifications
Extended EMC Immunity: NAMUR NE21, A Criterion, Burst< ±1% of span
EMC Immunity Influence< ±0.1% of span
Signal Dynamics, Output16 bit
Signal Dynamics, Input22 bit
AccuracyBetter than 0.05% of selected range
Long-Term Stability, Better Than±0.1% of span/year
Start-Up Time, Transmitter to displayMax. 5 s
ProgrammingHART
Signal/Noise Ratio> 60 dB
Response Time (Programmable)1 to 60 s
Response Time
Isolation Voltage, Test/Working1.5 kVAC/50 Vac
Isolation Voltage
Supply Voltage, DC: Other10 (12 - with backlight)...35 Vdc
Supply Voltage, DC: Ex ia, Intrinsically Safe10 (12 - with backlight)...30 Vdc
Supply
Common Specifications
BackLightSelectable ON/OFF
Number of Digits5
Display Resolution96 x 64 pixels
25 to 100 Hz±4 g
2 to 25 Hz±1.6 mm
VibrationEC 60068-2-6
Screw Terminal Torque0.4 Nm
Wire Size0.13 x 1.5 mm2/AWG 26 to 16 stranded wire
107.4 x 145 x 124 mm1.3/2.8 kg
Dimensions (HxWxD), Stainless Steel107.4 x 145 x 124 mm
Dimensions (HxWxD), Aluminum109.3 x 145 x 126 mm
DimensionsØ 110 mm
Mechanical Specifications
Protection DegreeIP54/IP66/IP68/type 4X
Relative Humidity0 to 100% RH (condensing)
Calibration Temperature20 to 28°C
Storage Temperature-40 to 85°C
Operating Temperature-20 to 85°C (with FKM Oring)
  • Thumbnail of document Manual - TXUN-FD Field Mounted Hart Protocol Temp. Transmitter
    Download