Skip to main content
Press Enter
OMEGA

TXUN-ST 2-Wire Programmable Transmitter w/Universal Input

2 Wire Hockey Puck Programmable Transmitter

Have questions? We're here to help!
Have questions? We're here to help!
Application
• Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
• Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
• Amplification of a bipolar mV signal to a standard 4 to 20 mA current signal.
Technical Characteristics
• Within a few seconds the user can program PR5331A to measure temperatures within all ranges defined by the norms.
• The RTD and resistance inputs have cable compensation for 2/3 and 4-wire connection.
• A continuous check of vital stored data for safety reasons.
• FM Approval Model Available (TXUN-FM)
• RTD, TC, &Omega , or mV Input
• Extremely High Measurement Accuracy
• 1.5 kVAC Galvanic Isolation
FM Certificate (TXUN-FM only)FM17US0013X
Approvals
EACTR-CU 020/2011
RoHS2011/65/EU
EMC2014/30/EU
Observed Authority Requirements
Of Span= of the presently selected range
Updating Time440 ms
Common Output Specifications
NAMUR NE43 Upscale/Downscale23 mA/3.5 mA
Sensor Error IndicationProgrammable 3.5 to 23 mA
Load Stability≤ 0.01% of span/100 Ω
Load (@ Current Output)≤ (Vsupply - 7.2)/0.023 [Ω]
Min. Signal Range16 mA
Signal Range4 to 20 mA
Current Output
Output Specifications
Input Resistance10 MΩ
Min. Measurement Range (Span)5 mV
Measurement Range-12 to 800 mV
Voltage Input
Sensor Error Current: When Detecting/Else: Nom. 33 µA/0 µA
Sensor Error DetectionYes
Cold Junction Compensation (CJC)< ±1.0°C
Thermocouple TypeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
TC Input
Linear Resistance Min to Max0 to 5000 Ω
Linear Resistance Input
Sensor Error DetectionYes
Effect of Sensor Cable Resistance (3/4-wire)< 0.002 Ω/Ω
Sensor CurrentNom. 0.2 mA
Cable Resistance Per Wire5 Ω (max.)
RTD TypePt100, Ni100, lin. R
RTD input
Max. Offset50% of selected max. value
Common Input Specifications
Input Specifications
Extended EMC Immunity: NAMUR NE21, A Criterion, Burst< ±1% of span
EMC Immunity Influence< ±0.5% of span
Effect of Supply Voltage Change< 0.005% of span/Vdc
Signal Dynamics, Output16 bit
Signal Dynamics, Input20 bit
AccuracyBetter than 0.05% of selected range
EEprom Error Check< 3.5 s
Signal/Noise RatioMin. 60 dB
ProgrammingLoop Link
Warm-Up Time5 min
Voltage Drop7.2 Vdc
Response Time (Programmable)1...60 s
Response Time
Isolation Voltage, Test/Working1.5 kVAC/50 Vac
Isolation Voltage
Internal Power Dissipation25 mW to 0.8 W
Supply Voltage7.2 to 35 Vdc
Common Specifications
25 to 100 Hz±4 g
2 to 25 Hz±1.6 mm
VibrationIEC 60068-2-6
Screw Terminal Torque0.4 Nm
Wire Size1 x 1.5 mm2 stranded wire
Weight Approx50 g
DimensionsØ 44 x 20.2 mm
Mechanical Specifications
Protection Degree (encl./Terminal)P68/IP00
Relative Humidity< 95% RH (non-cond.)
Calibration Temperature20 to 28°C
Operating Temperature-40 to 85°C
Environmental Conditions
  • Thumbnail of document Manual - TXUN-ST 2-Wire Programmable Transmitter w/Universal Input
    Download

    Manual - TXUN-ST 2-Wire Programmable Transmitter w/Universal Input

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more