ValProbe RT Temp Logger Flexible Sensors
Thin & flexible sensors for an extended temperature range from -85°C to +140°C, available as single, dual & 5-channel
The Kaye ValProbe RT Real Time Data Loggers come in many different configurations with rigid, bendable, and flexible sensors. The flexible Real Time Data Loggers are available with Single, Dual or 5 sensor configurations. Each flexible Real Time Data Logger provides 1000,000 samples per sensor of data storage and backup. The flexible Real Time Data Logger comes with a 40 inch flexible Teflon coated extension wire and a stainless tip for protection of the RTD sensor. The temperature range of the Logger is -85°C to +140°C.
The 5-channel version is an ideal and cost-effective alternative when multiple measurement points are needed in a single application, such as qualifying an incubator or refrigerator. The flexibility and length of the sensors make them excellent for applications such as sterilizer drains, SIP processes (Steam-In-Place), and penetration studies in vials. The compact and flexible sensor of the logger allows for use in most pharmaceutical applications and is ideal for penetration studies even with very small vials. This versatility makes the Kaye ValProbe RT Real-Time Data Loggers an excellent choice for complex and critical monitoring tasks in GxP environments.
- Temperature range: -85°C to 140°C
- Available sensors: Single, Dual, and 5-Channel
- Sensor length: 1,000 mm (40")
- Sensor tip diameter: 2.4 mm
- Sensor tip length: 25 mm (0.98")
| Sensor Type | Single, Dual and 5-Channel |
| Sensor Length | 40' inches 1000 mm |
| Tip Diameter | 0.095"; 2.4mm |
| Measurement Range | -85°C to 140°C |
| Accuracy | -85°C to 140°C, ±0.1°C |
| Logger Dimensions | Hight: 1,9'' / Diameter 1,4'' 48mm / 36mm |
| Logger Material | Stainless Steel 316L and Peek |
| Battery | Field replaceable - 3.6V Lithium |
| Sampling Rate | Starting at 1 sec |
| Data Storage | 100.000 Samples retained in non-volatile memory |
| Real-Time Clock Accuracy | < 15sec/day |
| Calibration | NVLAP (NVLAP LAB CODE 200913-0)/DAkkS Calibration |
| Verification | Automated User Verification capability |
| Sensing Element | Precision Platinum RTD |
| Environmental Temperature | -85°C to 140°C |
| Environmental Pressure | 0-5bar absolute |
| Environmental Humidity | 0-100% condensing |
| Regulatory Compliance | UL and CE |
- Steam sterilizers
- Steam in Place (SIP)
- Waterfall sterilizers
- Incubators
- Stability chambers
- Freezers
- Refrigerators
- Freeze dryger/Lyophilization
- Bioreactors and vessels