Skip to main content
Press Enter
Starting at $1,071.00CAD
Configure
Madgetech

VoltX Voltage Data Logger

Includes 4, 8, 12, and 16-channel DC voltage data loggers, accepts signals from common voltage sources

Starting at
$1,071.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The VoltX Series includes 4, 8, 12 and 16-channel DC voltage data loggers and are available in three voltage ranges: 160 mV, 3.2 V, and 32 V.

The VoltX Series accepts voltage signals from sensors, transducers and many other common voltage sources. Capable of measuring and recording up to 2,794,836 readings, users have the option to enable or disable channels to maximize memory capacity. There’s no interface necessary, the VoltX Series uses standard USB-A to Micro USB cable.

Using the MadgeTech Software, starting, stopping and downloading from the VoltX Series data loggers are simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.

• Available in 3 Measurement Ranges
• Memory Large Memory Capacity
• Accepts Signals from Common Voltage Sources
Memory4-channel: 698,709 readings per channel
8-channel: 349,354 readings per channel
12-channel: 232,903 readings per channel
16-channel: 174,677 readings per channel
(all channels enabled)
Reading Rate4 Hz up to 1 reading every 24 hours
Channels4, 8, 12, 16
LEDs1 per channel and 2 status LEDs
Battery Life18 months
MaterialBlack anodized aluminum
Dimensions 4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm)
8-channel: 2.70 in x 7.25 in x 1.22 in(65.6 mm x 184.2 mm x 31.0 mm)
12-channel: 2.70 in x 7.25 in x 1.68 in(65.6 mm x 184.2 mm x 42.7 mm)
16-channel: 2.70 in x 7.25 in x 2.14 in(65.6 mm x 184.2 mm x 54.4 mm)
Operating Environment-20 ºC to +60 ºC (-4 ºF to +140 ºF),0 %RH to 95 %RH non-condensing
Voltage Range±160 mV, ±3.2 V, -8 V to +32 V
Voltage Resolution160 mV: 0.02 mV
3.2 V: 0.004 mV
32 V: 0.004 mV
Voltage Calibrated Accuracy160 mV: ±0.032 mV
3.2 mV: ±0.0032 V
32 V: ±0.02 V

• Low Level Signal Monitoring
• Medical/Pharmaceutical
• Battery Studies
• Power Supply Monitoring
• Process Plants
• Environmental Studies
• Research and Development
• Replace Costly Strip Chart Recorders

  • Thumbnail of document Manual - VoltX Voltage Data Logger
    Download

    Manual - VoltX Voltage Data Logger

    Download
  • Thumbnail of document Data Sheet - VoltX Voltage Data Logger
    Download

    Data Sheet - VoltX Voltage Data Logger

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.