PCU Multi-Range Portable Calibration Unit

Secondary calibration standards that can go anywhere to verify the operation of flow equipment

Starting at
$4,320.00CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

When a single flow meter won’t cover all of your calibration needs, consider using a portable calibration unit (PCU). Alicat’s PCU-Series portable calibration units are secondary calibration standards that can go anywhere to verify the operation of flow equipment. Each PCU portable calibration unit comes with totalizers and high-accuracy calibration (0.4% reading + 0.2% full-scale range). These are housed inside a rugged industrial carrying case and powered by two (2) 9V  batteries (AC connections also included). The PCU includes integrated push-connect fittings for each meter, plus a copy of Alicat’s Flow Vision SC™ software. Available in stainless steel (PCUS) for corrosive gases and in the “Whisper” series (PCUW) for low pressure drop applications.

Alicat’s portable calibration units (PCU) combine three (3) battery-powered flow meters of complimentary ranges in a single case, each with totalizer and NIST-traceable high-accuracy calibration to a primary flow standard. With three overlapping measurement ranges, the PCU is capable of a total turndown of a million to one, making this an extremely versatile instrument.

• Combines up to 3 high-accuracy flow meters of varied ranges
• Quickly calibrate multiple instruments across a combined turndown range of up to 1,000,000:1
• Measures live flow rates and flow totals with NIST-traceable accuracy
• Model variations include low pressure drop (PCUW) and for corrosive/aggressive gases (PCUS)
• Flow meters houses within a rugged hard case to withstand drops if they should occur
• Includes COMPOSER™ gas composition firmware and Flow Vision SC™ software
• Multiple build and performance options
• NIST traceable
• Lifetime warranty

Accuracy at Calibration Conditions After Tare± (0.8% of Reading + 0.2% FS)
High Accuracy at Calibration Conditions After Tare*± (0.4% of Reading + 0.2% FS)
High Accuracy option not available for units ranged under 5 sccm or over 500 slpm
Repeatability± 0.2% FS
Zero Shift and Span Shift0.02% FS / ºCelsius / Atm
Operating Range0.5% - 100% FS
Turndown Ratio200:1
Maximum Measurable Flow Rateup to 128% FS (Gas Dependent)
Typical Response Time10 ms (adjustable)
Warm-up Time< 1 s
Standard Mass Reference Conditions (STP)25ºC & 14.696 PSIA
Operating Temperature-10°C - 60ºC
Humidity Range (Non-Condensing)0% - 100%
Maximum Internal Pressure (Static) M Series: 145 PSIG
Whisper: 45 PSIG
Maximum Allowable Instantaneous Differential Pressure Across Device (Inlet to Outlet)M Series: 75 PSID
Whisper: 15 PSID
Proof Pressure175 PSIG
Ingress ProtectionIP40
Wetted Materials303 & 302 Stainless Steel, Viton®, Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene
Sulfide, Heat Cured Epoxy, Aluminum, Gold, Silicon, Glass

• Calibration of multiple flow instruments

  • Thumbnail of document Manual - PCU Multi-Range Portable Calibration Unit
    Download

    Manual - PCU Multi-Range Portable Calibration Unit

    Download
  • Thumbnail of document Data Sheet - PCU Multi-Range Portable Calibration Unit
    Download

    Data Sheet - PCU Multi-Range Portable Calibration Unit

    Download

Accessories

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more