Skip to main content
Press Enter
OMEGA

DP8PT-330-EIP Platinum Series Universal Input Digital Panel Meters

PLATINUM™ Series Digital Panel Meters

Normally ships in
2-3 weeks
Have questions? We're here to help!
Have questions? We're here to help!

Supported Applications

The DPPT Series is the OMEGA PLATINUM™ family of microprocessor-based universal-input digital panel meters, built for high-accuracy temperature and process indication in industrial control panels. A bright 3-color (red, green, amber) 9-segment LED display with a wide viewing angle makes readings easy to see across a control room, machine console, or process skid.

Because each meter accepts thermocouples, RTDs, thermistors, and process voltage or current signals, the DPPT Series covers a wide span of monitoring and control tasks — from furnace and oven temperature to flow, pressure, and load signals delivered by process transmitters and strain sensors. Flexible alarm programming, isolated analog retransmission, and optional serial and Ethernet communications extend the series into alarming, control, and networked data acquisition roles.

Operating Conditions & Performance

DPPT meters run from a universal supply of 90 to 240 Vac ±10%, 50 to 400 Hz, or 110 to 375 Vdc, with a low-voltage option of 12 to 36 Vdc. A 24-bit sigma-delta converter samples at 20 readings per second and resolves temperature to 0.1°, while process inputs resolve to the 10 microvolt level.

The universal input handles wide, sensor-specific ranges: a J thermocouple spans -210 to 1200°C (-346 to 2192°F), a K thermocouple reaches -160 to 1372°C (-256 to 2502°F), and thermocouple accuracy is as tight as 0.4°C (0.7°F). RTD inputs cover 100 Ω, 500 Ω, and 1000 Ω platinum sensors with accuracy to 0.3°C, and process inputs read voltage to ±100 mV and ±10 Vdc or current across 0 to 24 mA at 0.03% FS.

The meters operate over an ambient range of 0 to 50°C (32 to 122°F) at 90% RH non-condensing. The 1/32 and 1/16 DIN models carry a NEMA 4X (IP65) front bezel for wash-down panel faces, while the 1/8 DIN models use a NEMA 1 front bezel. All sizes share a common 127 mm case depth.

Configuration Options

The DPPT Series is configured through a structured model number, DP<Size>Pt - <Alarm Outputs> - <Communications> - <Power>, so a meter can be tailored to the panel, the alarm scheme, the network, and the available power:

• DIN size — 1/32, 1/16, and 1/8 DIN formats fit the available cutout. The 1/32 and 1/16 DIN models drive a 10.2 mm digit height, while the larger DP8Pt/DP8EPT display uses a 21 mm digit height.
• Alarm outputs — the -330 option adds two mechanical relays for alarm and control; SPDT and SPST relays are rated 250 Vac or 30 Vdc at 3 A, alongside an SSR rated 20 to 265 Vac.
• Communications — USB is standard on every model; the -C24 option adds software-selectable RS232/RS485 serial, and Ethernet-equipped models carry the -EIP suffix. Ethernet options are not available on 1/32 DIN models.
• Power — the -DC suffix selects the low-voltage DC power input in place of the standard universal AC supply.

Key Product Differences

The lineup is built from three DIN-size platforms, each expandable with alarm, communications, and power options:

• DP32Pt — 1/32 DIN universal-input meter (for example DP32Pt-C24 with serial, or DP32Pt-330-C24-DC with two relays, serial, and DC power).
• DP16Pt — 1/16 DIN universal-input meter, offered with relays, serial, Ethernet, and DC options (for example DP16Pt-330-DC and Ethernet-capable DP16Pt-EIP).
• DP8Pt and DP8EPT — 1/8 DIN universal-input meters with the larger LED display and the full range of alarm, communications, and power options.

Across the family, thermocouple, RTD, thermistor, and process inputs are common to every size, so a configuration differs only in cutout, alarm and communication options, and power input rather than in core measurement capability.

• Strain & Bridge Inputs, 6 Digit Display and Upgraded Platinum Software Now Available
• Super High Performance (20 Samples / Sec), High Accuracy
• Extremely Versatile yet Easy and Intuitive to Use
• Bright 3-Color (RED, GREEN, and AMBER) 9 Segment LED Display with Wide Viewing Angle
A/D Conversion24-bit sigma delta
Accuracy0.03 % FS
Additional Features 1Programmable 3 Color Display
ApprovalsUL, cUL, CE, UKCA
CMRR120 dB
ConfigurationDifferential
Cutout Dimensions45 mm
Data Interface NoteEthernet Standards Compliance: IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET Protocols: OMEGA ASCII, MODBUS® ASCII/RTU
Display Range-1999 to 9999
External Fuse RequiredTime-Delay, UL 248-14 Listed: 100 mA/250 V; 400 mA/250 V (low voltage option) ;Time-Lag, IEC 127-3 Recognized: 100 mA/250 V; 400 mA/250 V (low voltage option)
Frequency50 to 400 Hz
Height48 mm
Impedance InputProcess/Strain: 10M Ω for ±100 mV, 1M Ω for other voltage ranges ;Process Current: 5 Ω ;Thermocouple: 10K Ω max
Input Current4 to 20 mA, 0 to 24 mA
Input TypeThermocouple, RTD, Thermistor, Current, Voltage, Strain
Input Voltage-100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
IsolationPower to Input/Output: 2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option) Power to Relays/SSR Outputs: 2300 Vac per 1 min test Relays/SSR to Relay/SSR Outputs: 2300 Vac per 1 min test RS232/RS485 to Inputs/Outputs: 500 Vac per 1 min test
Length127 mm
Measuring RangeProcess Voltage: ±50 mV, ±100 mV, ±1, ±10 Vdc;Process Current: Scalable within 0 to 24 mA;Thermocouple;Type J: -210 to 1200 °C ;Type K: -270 to 160 °C and -160 to 1372 °C;Type T: -270 to -190 °C and -190 to 400 °C;Type E: -270 to -220 °C and -220 to 1000 °C;Type R: -50 to 40 °C and 40 to 1788 °C;Type S: -50 to 100 °C and 100 to 1768 °C;Type B: 100 to 640 °C and 640 to 1820 °C;Type C: 0 to 2320 °C;Type N: -250 to -100 °C and -100 to 1300 °C;RTD;Pt, 0.00385, 100 Ω, 500 Ω, 1000 Ω: -200 to 850 °C;Pt, 0.003916, 100 Ω: -200 to 660 °C;Pt, 0.00392, 100 Ω : -200 to 660 °C;Thermistor;2252 Ω: -40 to 120 °C;5K Ω: -30 to 140 °C;10K Ω: -20 to 150 °C
Number of Inputs1
Operating Temperature, Max50 °C
Operating Temperature, Min0 °C
Operating Temperature Note0 to 50°C (32 to 122°F), 90% RH non-condensing
PolarityBipolar
Power Consumption4 W
Reading Rate20/sec
Relative Humidity0.9
Resolution0.1° temperature; 10 µV process
RTD Input Range100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves
Sampling Rate20 Hz (20 updates/second)
Sensor/Transmitter Power5, 10, 12 and 24 Vdc @ 25 mA
Sensor/Transmitter Power NoteFirmware selectable (no jumpers to set) to 5, 10, 12, and 24 Vdc @ 25 mA
Series IDDPPT-Series
Strain Input± 50 mV, ± 100 mV
Supply Power Note90 to 240 Vac ±10%, 50 to 400 Hz*, 110 to 375 Vdc, equivalent voltage
Temperature StabilityRTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C
Thermistor Input Range2252 Ω, 5K Ω, 10K Ω
Thermocouple TypeJ, K, T, E, R, S, B, C, N
Warm Up Time30 mins
Width48 mm
  • Download

    Data Sheet - DP8PT-330-EIP Platinum Series Universal Input Digital Panel Meters

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more