FLR1007 SS Low Flow Turbine Flow Meter w/Optional Display

Air/Water Flow Sensors with 0 to 5 Vdc Output

Have questions? We're here to help!
Have questions? We're here to help!

 FLR1000 Series flow sensors can measure extremely low flow rates from 20 mL/min to 500 L/min. These sensors are suitable for a wide variety of industrial, commercial, and laboratory flow applications. Not for use with Hydrogen or Helium. FLR1000 Series flow sensors operate on 12 Vdc power and are designed for incorporation into data acquisition systems that supply 12.5 Vdc to sensors and receive 0 to 5 Vdc linear signals in return. Because of their cost effectiveness, FLR1000 Series units may replace conventional glass tube and ball flow meters in applications in which an electrical signal proportional to flow rate is desired.

 
The FLR1000 Series uses a Pelton-type turbine wheel to determine the flow rate of the gas. The rotation rate of the turbine wheel is linear over a wide dynamic range. The electro-optical system consists of a diode emitting energy in the infrared spectrum. Light energy is alternatively reflected and absorbed from "spokes" deposited on the small turbine wheel. This reflected light energy is detected by a photodiode. Thus, as the turbine wheel rotates in response to gas flow rate, electrical pulses are generated. Processing circuitry provides a DC voltage output proportional to the flow rate. For example, output signal is 1.0 Vdc at 20% of rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc at 80% of rated flow, and 5.0 Vdc at 100% of rated flow. Sensors can handle 20% above their rated flow without being damaged
• 0 to 5 Vdc Linear Output Signal
• Power Input 12 Vdc or 24 Vdc (depending on the model)
• Ranges from 20 to 100 ml/min, 100 to 500 L/min
• 1% Accuracy for Liquids/3% Accuracy for Gasses
FLR1000 Series
Accuracy±3% FS
Display3½-digit LCD, 22 mm (7/8") H
Output Signal0 to 5 Vdc, adjustable ±20% (typical)
Power Requirements11.5 to 15 Vdc regulated, 30 mA (typical)
Standard Sensor Material40% glass filled polyphenelene sulfide, glass window, stainless steel bearing support; sapphire shaft and bearing; FKM rubber O-rings standard
Pressure Rating40 psi at 20°C (68°F) for gas, 100 psi for liquid, 500 psi for brass units using liquid services
Temperature Rating0 to 50°C (32 to 122°F)
Temperature Sensitivity±0.2%/°C
Linearity±3% FS
Repeatability:±0.5% FS from 50 to 100% of rated max flow for gas; ±0.2% FS for liquid
Cable Assembly0.9 m (3') cable length
Dimensions
Display76 x 44 x 89 mm (3 x 1.75 x 3.5")
Non-Display60 x 42 x 37 mm (2.35 x 1.65 x 1.25")
Pressure Sensitivity±0.07%/mm Hg (using air at 1 to 3 atm)
MountingHoles for #4 screw provided
Voltage Output Models11.5 to 12.5 Vdc (0.4 W @ 12 Vdc)
Current Output Models18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA
  • Thumbnail of document Data Sheet - FLR1007 SS Low Flow Turbine Flow Meter w/Optional Display
    Download

    Data Sheet - FLR1007 SS Low Flow Turbine Flow Meter w/Optional Display

    Download

Accessories

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more